Model/Brand/Package
Category/Description
Inventory
Price
Data
-
Category: power relayDescription: Industrial Relay EMUG 45-8REL/KSR-G 24/151951+$2861.958010+$2835.940225+$2822.931350+$2809.9224100+$2796.9135150+$2783.9046250+$2770.8957500+$2757.8868
-
Category: power relayDescription: PSR-TRISAFE-S The safety controller PSR-TRISAFE-S is an independent controller with 20 safety inputs, 4 safety outputs, and 2 safety ground switching outputs. If additional safety outputs or safety relay outputs are required, the standard safety relay expansion module can be hard wired to the safety outputs of the PSR-TRISAFE-S module. System designers should consider adding safety extension relays for two reasons: (a) the PSR-TRISAFE-S module does not have sufficient safety outputs; (b) A safety relay circuit is required to switch voltages other than 24V DC. The PSR-TRISAFE-S module is a 24V solid-state device. Intuitive 3-step software operation protection: password, used to defend against unauthorized changes in hardware and software security logic: defend against unwanted changes in security logic, press the CONFIRM button on the front of the device. All commonly used security functions can be easily and flexibly used: emergency stop and anti-theft door monitoring, non-contact switch, security sensor, laser scanner, optical equipment (mute or non mute), as well as security mode selection, start switch, dual hand control device 2 clock outputs, 4 alarm outputs, and ground conversion outputs, increasing the security of the monitoring circuit. # # # Recognized TUV FS, UL, cUL # # EN954-1 conforms to Class 4, ISO 13849-1 conforms to PLe, IEC 62061 conforms to SILC L 3, used for machine and system engineering SIL3 compliant with IEC 61508, for process industry # # # safety controllers5606
-
Category: Industrial Relay/UniversalDescription: General Purpose Relays UMK-16 RELS/KSR-AC/1/PLC3596
-
Category: solid state relayDescription: TERM BLOCK75531+$366.920210+$357.348350+$350.0099100+$347.4574200+$345.5431500+$342.99061000+$341.39532000+$339.8000
-
Category: power relayDescription: 24VDC 8A No latch48551+$72.180910+$69.0426100+$68.4777250+$68.0383500+$67.34791000+$67.03412500+$66.59475000+$66.2181
-
Category: Industrial Relay/UniversalDescription: Electromechanical Relay 24VDC 1.14KΩ 8A SPDT (( 22.5mm 62.5mm 75mm)) DIN Rail Module Relay40391+$736.791110+$710.938850+$707.7073100+$704.4757150+$699.3053250+$694.7811500+$690.25691000+$685.0865
-
Category: power relayDescription: Prefabricated relay module with pullback spring wiring, including: relay base, plug-in industrial relay with built-in LED, freewheeling diode, manual operating lever, and fixed clamp. Input voltage: 24V DC, 2PDT, 10A74671+$126.994510+$123.681650+$121.1417100+$120.2583200+$119.5957500+$118.71231000+$118.16012000+$117.6080
-
Category: Industrial Relay/UniversalDescription: RIF0 The professional series of power relay modules includes a relay base with an ejector and multiple layers of gold contacts or power contact relays. Adopting push in connection technology, easy to wire, easy to manipulate and expand range, plug-in display/suppressor module 1 and 2 contact options 5ms typical response time, yellow LED indicator, shock absorber diode protection circuit # # # power relay79821+$97.417710+$93.1821100+$92.4197250+$91.8267500+$90.89491000+$90.47132500+$89.87845000+$89.3701
-
Category: power relayDescription: Electromechanical Relay 48VDC 48VAC 6A SPDT (( 10.6mm 62.5mm 75mm)) DIN Rail Module Relay70951+$496.977110+$484.012550+$474.0729100+$470.6157200+$468.0228500+$464.56561000+$462.40482000+$460.2440
-
Category: power relayDescription: Modular part; Electromechanical Output Relay; 125V in; 250V; 6A out; DIN rail mnt13651+$195.552910+$190.451550+$186.5405100+$185.1801200+$184.1598500+$182.79951000+$181.94922000+$181.0990
-
Category: solid state relayDescription: Phoenix Contact PLC - 290038425251+$624.924110+$602.996950+$600.2560100+$597.5151150+$593.1297250+$589.2924500+$585.45521000+$581.0697
-
Category: power relayDescription: 110VDC 6A No latch33701+$492.420810+$479.575050+$469.7266100+$466.3011200+$463.7319500+$460.30641000+$458.16542000+$456.0245
-
Category: power relayDescription: Relay; Monitor; E-Mech; Voltage; DPDT; Cur-Rtg 3; 5A; Ctrl-V 24-240AC/DC; Vol-Rtg 250AC93451+$1987.987110+$1969.914525+$1960.878250+$1951.8419100+$1942.8056150+$1933.7693250+$1924.7330500+$1915.6967
-
Category: power relayDescription: Industrial Relay ST-REL7-HW 60/4X2119201+$1433.293410+$1420.263525+$1413.748550+$1407.2335100+$1400.7186150+$1394.2036250+$1387.6886500+$1381.1736
-
Category: power relayDescription: 120VAC/DC 3A No latch61371+$2024.093510+$2005.692725+$1996.492250+$1987.2918100+$1978.0914150+$1968.8910250+$1959.6905500+$1950.4901
-
Category: power relayDescription: Modular part; Electromechanical Output Relay; 24V in; 36VDC; 50mA out; DIN rail mnt51891+$268.702110+$261.692550+$256.3184100+$254.4492200+$253.0473500+$251.17811000+$250.00982000+$248.8415
-
Category: power relayDescription: PSR-SCP Series Safety Controller, 20 Safety Inputs, 4 Safety Outputs, 24V dc5322
-
Category: solid state relayDescription: Electromechanical Relay 230VAC 1A (( 6.2mm 86mm 80mm)) DIN Rail PLC Relay55111+$630.217110+$608.104250+$605.3401100+$602.5760150+$598.1534250+$594.2837500+$590.41391000+$585.9913
-
Category: solid state relayDescription: PLC-The oscilloscope interface relay PLC-OSC series sensor interface includes PLC-BSC basic terminal block, with screw connection, push in connection solid-state relay and PLC-OSC series solid-state relay. Screw connection yellow LED indicator working temperature: -25 º C to 60 º C, also provides a wide range of accessories # # # Recognized cUL, GL, UL # # Standards IEC60664, EN50178, IEC62103 # # # Interface relay19311+$663.433310+$640.154950+$637.2451100+$634.3353150+$629.6796250+$625.6059500+$621.53221000+$616.8765
-
Category: solid state relayDescription: Phoenix Contact - 298213990721+$369.206410+$359.574950+$352.1908100+$349.6224200+$347.6961500+$345.12771000+$343.52242000+$341.9172
-
Category: solid state relayDescription: Electromechanical Relay 24VDC 13A (( 110mm 62mm 84mm)) DIN Rail Connector Relay73841+$3041.559410+$3013.908925+$3000.083650+$2986.2583100+$2972.4331150+$2958.6078250+$2944.7825500+$2930.9572
-
Category: Safety typeDescription: Multi-application Modular System - PSR-SPP Series This can be quickly and reliably assembled to form a tailor-made safety solution. To connect using TBUS correctly you will need one PSR-TBUS per module. For the last additional module use one PSR-TBUS-TP instead, this will close the feedback loop. The interface module is used for the connection of up to four safety sensors with NC/NO contacts to the safety relay PSR-SDC4, with screw connection. Quick system extension up to 10 modules, offering a safety system with up to 42 contacts Automatic identification of desired operating mode, no need to set switches or define parameters The system is based on a master relay (PSR-SDC) that monitors e-stops, guard doors (interlock or non-contact) and optical devices (e.g. light curtains) Safe cross-wiring with T-BUS renders the usual cross-wiring of supply voltage, enable signal and confirmation path redundant. Making commissioning and future expansion simple 24Vdc supply voltage Semiconductor output Depending on the wiring Safety category 2 or 4 can be maintained One or Two channel switches are used for control Note: The device has a rear interface for the DIN Rail connector T-BUS. Via this T-BUS interface extension devices PSR-URM4-B (undelayed contacts) and PSR-URD (drop-out delay contacts) can be controlled and monitored over one channel. These in combination form a T-BUS unit, the feedback path must be connected to the final (right hand) extension device (see datasheet for more details) or by using connection plug PSR-TBUS-TP ### Configurable safety relay46251+$1312.983110+$1301.046925+$1295.078850+$1289.1107100+$1283.1426150+$1277.1745250+$1271.2064500+$1265.2383
-
Category: power relayDescription: Multi-application Modular System - PSR-SPP Series This can be quickly and reliably assembled to form a tailor-made safety solution. To connect using TBUS correctly you will need one PSR-TBUS per module. For the last additional module use one PSR-TBUS-TP instead, this will close the feedback loop. The interface module is used for the connection of up to four safety sensors with NC/NO contacts to the safety relay PSR-SDC4, with screw connection. Quick system extension up to 10 modules, offering a safety system with up to 42 contacts Automatic identification of desired operating mode, no need to set switches or define parameters The system is based on a master relay (PSR-SDC) that monitors e-stops, guard doors (interlock or non-contact) and optical devices (e.g. light curtains) Safe cross-wiring with T-BUS renders the usual cross-wiring of supply voltage, enable signal and confirmation path redundant. Making commissioning and future expansion simple 24Vdc supply voltage Semiconductor output Depending on the wiring Safety category 2 or 4 can be maintained One or Two channel switches are used for control Note: The device has a rear interface for the DIN Rail connector T-BUS. Via this T-BUS interface extension devices PSR-URM4-B (undelayed contacts) and PSR-URD (drop-out delay contacts) can be controlled and monitored over one channel. These in combination form a T-BUS unit, the feedback path must be connected to the final (right hand) extension device (see datasheet for more details) or by using connection plug PSR-TBUS-TP ### Configurable safety relay39071+$1698.962110+$1683.517025+$1675.794450+$1668.0719100+$1660.3493150+$1652.6268250+$1644.9042500+$1637.1817
-
Category: power relayDescription: Electromechanical Relay 24VDC 285.71Ω 6(NO)/3(NC)A 4PST-NO/SPST-NC (( 22.5mm 114.5mm 99mm)) DIN Rail Safety Relay22811+$4413.588310+$4373.464825+$4353.403050+$4333.3412100+$4313.2795150+$4293.2177250+$4273.1559500+$4253.0942
-
Category: power relayDescription: Safety relay PSR-SPP -24DC/SSM/2X184481+$4513.741110+$4472.707125+$4452.190150+$4431.6731100+$4411.1561150+$4390.6391250+$4370.1221500+$4349.6051
-
Category: power relayDescription: Electromechanical Relay 24VDC 6(NO)/3(NC)A 5PST-NO/SPST-NC (( 45mm 114.5mm 112mm)) DIN Rail Safety Relay70791+$2784.070310+$2758.760625+$2746.105750+$2733.4508100+$2720.7960150+$2708.1411250+$2695.4862500+$2682.8314
-
Category: power relayDescription: Electromechanical Relay 120VDC 120VAC 6A 5PST-NO/DPST-NC( (22.5mm 114.5mm 99mm)) DIN Rail Safety Relay68001+$1161.100610+$1150.545125+$1145.267450+$1139.9897100+$1134.7120150+$1129.4342250+$1124.1565500+$1118.8788
-
Category: power relayDescription: Electromechanical Relay 24VDC 160Ω 6A 5PST-NO/SPST-NC (( 45mm 114.5mm 99mm)) DIN Rail Safety Relay81561+$4614.244810+$4572.297125+$4551.323350+$4530.3494100+$4509.3756150+$4488.4018250+$4467.4279500+$4446.4541
-
Category: power relayDescription: PSR Safety relays are used as standards in process engineering for fault protection controllers in the manufacturing industry. In this context, the use of safety coupled relays in actuator power regulation and electrical insulation has significantly increased due to the fact that actuators often require more current or other voltage than the controller can provide. In addition, the digital output of the fault protection controller runs automatic self-test at regular intervals to detect faults. However, the test pulses involved often lead to premature wear of the relay. Using its integrated testing pulse and control circuit to regulate power consumption, all FSP devices consider the special requirements of the fault safety controller. ###The emergency stop coupling relay connects the digital output signal from the fault safety controller to peripheral devices (valves, etc.) used for electrical insulation and power adaptation. It has one enable current path (768-5134 and 801-6075) and two enable current paths (712-5263, 712-5266, 712-5260, and 712-5279). The 17.5mm slender housing has a long service life due to filtering controller test pulses. The enable current path is equipped with installed and replaceable fuses, and the forced conductive contacts comply with EN 50205. According to the integrated signal contact simple protection test, it complies with IEC 61508 up to SIL 2 (712-5263 and 712-5266) and up to SIL 3 (768-5134, 801-6075). 712-5260 Emergency stop and safety door monitoring single channel and dual channel control (666-7084 and 801-5956) single channel control (666-7022 and 801-5930) manual and automatic activation up to 3 enable current paths 24-230V wide range input (666-7084 and 801-5956) with reduced turn-on current, therefore suitable for connection to fault protection controller (PSR-ESP4) up to Cat. 4/PL e in accordance with ISO 13849-1, SILCL 3 in accordance with IEC 62061, SIL 3 in accordance with IEC 61508 # # F&G Coupling relay, used for fault protection controller, can output digital signal22861+$2758.160910+$2733.086725+$2720.549650+$2708.0125100+$2695.4754150+$2682.9383250+$2670.4012500+$2657.8641
-
Category: power relayDescription: Electromechanical Relay 24VDC 24VAC 6A (22.5x114.5x112)mm DIN Rail Safety Relay88191+$1850.134010+$1833.314625+$1824.904950+$1816.4952100+$1808.0855150+$1799.6758250+$1791.2661500+$1782.8564